Compact thermal mass flow meter (pro-inline)

Hide thumbs Also See for S418:

  • Instruction and operation manual (28 pages)
1
2
Table Of Contents 3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
  • Contents
  • Table of Contents
  • Bookmarks

Table of Contents

  • Table of Contents

  • Safety Instructions

  • Registered Trademarks

  • RF Exposure Information and Statement

  • Application

  • Features

  • Technical Data

  • General Data

  • Electrical Data

  • Data Logger

  • Output Signals

  • Accuracy

  • Additional Data for Models with Pressure Sensor

  • Dimensional Drawing

  • Installation

  • Installation Considerations

  • LED Indicators

  • Electrical Connection

  • Signal Outputs

  • Analog Output

  • Pulse Output

  • Modbus Interface

  • Modbus Information

  • Connect Several S418 to Modbus Master

  • M-Bus Outptut

  • Connection between S418 Outputs and Customer Equipment

  • Configuration

  • Read and Analysis of Measurement Data

  • Data Logger

  • Operations

  • Logger Configuration

  • Data Read-Out and Analysis

  • Calibration

  • Disposal or Waste

  • Appendix - Specifications

  • Flow Ranges

  • Order Table

  • Error Codes

Advertisement

Quick Links

Download this manual

English

Instruction and operation manual

S418

Compact Thermal Mass Flow Meter

(Pro-Inline)

Table ofContents

NextPage
  • 1
  • 2
  • 3
  • 4
  • 5

Advertisement

Table of Contents

SUTO S418 INSTRUCTION AND OPERATION MANUAL Pdf Download (2)

Related Manuals for SUTO S418

  • Accessories SUTO S418 Instruction And Operation Manual

    Thermal mass flow sensor (with data logger) (28 pages)

  • Measuring Instruments SUTO S418-V Instruction And Operation Manual

    Vacuum flow meter with data logger (28 pages)

  • Measuring Instruments SUTO S418-V Instruction And Operation Manual

    Compact thermal mass flow meter for vacuum application (pro-inline) (32 pages)

  • Measuring Instruments SUTO S415 Instruction And Operation Manual

    Thermal mass flow sensor (24 pages)

  • Measuring Instruments SUTO S415 Instruction And Operation Manual

    Compact thermal mass flow meter (eco-inline) (32 pages)

  • Measuring Instruments SUTO S430 Instruction And Operation Manual

    Pitot tube flow sensor (48 pages)

  • Measuring Instruments SUTO S430 Instruction And Operation Manual

    Pitot tube flow meter for wet air (insertion) (52 pages)

  • Measuring Instruments SUTO S452 Instruction And Operation Manual

    Thermal mass flow meter for heavy duty and ex applications (inline) (28 pages)

  • Measuring Instruments SUTO S401 Instruction And Operation Manual

    Thermal mass flow meter (insertion) (44 pages)

  • Measuring Instruments SUTO S 460 Instruction And Operation Manual

    Ultrasonic flow meter (24 pages)

  • Measuring Instruments SUTO S450 Instruction And Operation Manual

    Thermal mass flow meter for heavy duty and ex applications (36 pages)

  • Measuring Instruments SUTO S462 Instruction And Operation Manual

    Ultrasonic flow meter (24 pages)

  • Measuring Instruments SUTO S461 Instruction And Operation Manual

    Ultrasonic flow meter (40 pages)

  • Measuring Instruments SUTO S461 Instruction And Operation Manual

    Ultrasonic flow meter for liquids (clamp-on) (48 pages)

  • Measuring Instruments SUTO S431 OEM V2 Instruction And Operation Manual

    Pitot tube compressor flow meter (inline) (36 pages)

  • Measuring Instruments SUTO S4C-FS Instruction And Operation Manual

    Smartphone app for air and gas flow meter (20 pages)

Summary of Contents for SUTO S418

  • Page 1 English Instruction and operation manual S418 Compact Thermal Mass Flow Meter (Pro-Inline)
  • Page 2 The device is destined exclusively for the described application. SUTO offers no guarantee for the suitability for any other purpose. SUTO is also not liable for consequential damage resulting from the delivery, capability or use of this device.
  • Page 3: Table Of Contents

    9.2 Pulse Output...............18 9.3 Modbus Interface..............19 9.3.1 Modbus Information............19 9.3.2 Connect Several S418 to Modbus Master......20 9.4 M-Bus Outptut..............24 9.5 Connection between S418 Outputs and Customer Equipment..24 10 Configuration................26 11 Read and Analysis of Measurement Data........27 11.1 Data Logger..............27 11.2 Operations................28 11.2.1 Logger Configuration............28...
  • Page 4: Safety Instructions

    • Consider all regulations for electrical installations. • The system must be disconnected from any power supply during maintenance. • Any electrical work on system is only allowed by authorized qualified personal. S418...
  • Page 5 • Always observe the direction of the flow when installing the sensor. The direction is indicated on the housing. • Do not exceed the maximum operating temperature at the sensors tip. • Avoid condensation on the sensor element as this will affect accuracy enormously. S418...
  • Page 6: Registered Trademarks

    • Avoid direct UV and solar radiation during storage. • For the storage the humidity must be <90% with no condensation. 2 Registered Trademarks Trademark Trademark owner SUTO ® SUTO iTEC MODBUS Modbus Organization, Hopkinton, USA ® Android™, Google LLC Google Play...
  • Page 7: Rf Exposure Information And Statement

    • Consult the dealer or an experienced radio/TV technician for help • This device and its antenna(s) must not be co-located or operating in conjunction with any other antenna or transmitter. S418...
  • Page 8: Application

    4 Application 4 Application The S418 is a Compact Thermal Mass Flow Meterthe designed to measure the consumption of compressed air and other gases within the permissible operating parameters. These parameters are stated in chapter 6 Technical Data. The S418 can measure the following parameters: •...
  • Page 9: Technical Data

    See dimensional drawing on page 12. Display 4-digit LED display Tube diameter DN8, DN15, DN20, DN25, DN32 Process connection: G inner thread ISO 228-1 Weight 0.43 kg (DN8), 0.46 kg (DN15) 0.96 kg (DN20), 0.97 kg (DN25), 1.7 kg (DN32) S418...
  • Page 10: Electrical Data

    Use the mobileApp S4C-FS (Free for download on Google Play Store) Logger readout Use Windows-based software - S4A via USB (Free for download on the SUTO Website) 6.4 Output Signals Analogue output Signal: 4 ... 20 mA, isolated Scaling: 0 to max flow...
  • Page 11: Accuracy

    0 … 1.0 MPa Remark: The total consumption value is saved to the permanent memory every 5 minutes. If within these 5 minutes the device is powered off, it will restore the last consumption value which was saved in the last cycle. S418...
  • Page 12: Dimensional Drawing

    7 Dimensional Drawing 7 Dimensional Drawing Unit: mm DN8/DN15 S418...
  • Page 13 7 Dimensional Drawing DN20/DN25 S418...
  • Page 14 7 Dimensional Drawing DN32 S418...
  • Page 15: Installation

    8 Installation 8 Installation S418 is delivered with following components: Qty. Description Order no. S695 4180 S695 4181 S695 4182 S695 4183 S695 4184 S418 Compact Thermal Mass Flow Meter S695 4185 S695 4186 S695 4187 S695 4188 S695 4189...
  • Page 16: Led Indicators

    Always observe operating temperature and humidity as stated in the the technical data. • It is strongly recommend not to install S418 permanently in wet air/gas conditions, which exists usually right after a compressor outlet.
  • Page 17: Electrical Connection

    5 m cable with a M8 connector on one side and open wires on the other side. To operate the S418, one cable connection is sufficient. However if the pulse output is to be used or the supply and signal should be on separate cables, a second connection cable must be ordered.
  • Page 18: Signal Outputs

    The device outputs one pulse per a consumption unit. This pulse output can be connected to an external pulse counter to count the total consumption. The number of m per second are summed up and indicated after one second. Pulse length depends on flow rate. S418...
  • Page 19: Modbus Interface

    SEEEEEEE) (EMMMMMMM *) Byte 0 Byte 3 UINT32 1-0-3-2 Byte 1 Byte 2 INT32 Byte 1 Byte 0 UINT16 INT16 Byte 1 Byte 0 UINT8 XXX * DATA INT8 * S: Sign, E: Exponent, M: Mantissa, XXX: no value S418...
  • Page 20: Connect Several S418 To Modbus Master

    FLOAT 4-byte 9.3.2 Connect Several S418 to Modbus Master The S418 with Modbus/RTU interface can be easily daisy-chained to a Modbus Master device. This master can be either SUTO displays and gateways or any third-party Modbus/RTU master. Through this method you can add up to 16 flow meters to the master device.
  • Page 21 (A553 0123). • The shield must be connected at one end to the master GND connection. • At the end of the bus, a 120 Ohm resistor should be placed a termination resistor. See the below picture for details. S418...
  • Page 22 9 Signal Outputs 9.3.2.3 Create Daisy-Chain using RS-485 Splitter To connect the S418 to the daisy-chain, the RS-485 splitter (A554 3310) and the M8 to M12 converter cable (A553 0161) are needed. Furthermore place a M12 termination resistor (C219 0055) at the last splitter in the daisy-chain, as show in the figure below.
  • Page 23 9.3.2.1 Modbus/RTU Cable Length. Other connection topologies are not recommended and must be avoided. Avoid a connection of Slaves to the master in ring or star topology. Avoid a star topology Avoid a ring topology S418...
  • Page 24: M-Bus Outptut

    4-byte 9.5 Connection between S418 Outputs and Customer Equipment This section provides figures to show how outputs supported by the S418 connect with the customer equipment. In the following figures, the SUTO Instrument indicates the S418. Analog output (Isolated) S418...
  • Page 25 9 Signal Outputs Pulse output (passive) Modbus/RTU output M-Bus output S418...
  • Page 26: Configuration

    10 Configuration 10 Configuration To change any settings on the S418, please download and install the service App S4C-FS which is available on the Google Play store or our Website. This App works on any Android or iOS system with Bluetooth supported.
  • Page 27: Read And Analysis Of Measurement Data

    • The S418 log file supports up to 5.6 million records due to its memory size, which is equivalent to 64-day data at the one- second sampling rate.
  • Page 28: Operations

    11 Read and Analysis of Measurement Data 11.2 Operations 11.2.1 Logger Configuration You can control and configure the S418 data logger by using the S4C-FS App. Detailed steps are as follows. 1. Install and launch the S4C-FS App. For more information, see the S4C-FS Instruction and Operation Manual.
  • Page 29: Calibration

    The device, the accessories and its packings must be disposed according to your local statutory requirements. The dispose can also be carried by the manufacturer of the product, for this please contact the manufacturer. S418...
  • Page 30: Appendix - Specifications

    Note: To calculate flow ranges based on pipe and reference conditions in your site, download and install the "Flow range calculator" tool for free from http://www.suto-itec.com. To fast access the tool download page, enter "flowrange" (without spaces) in the search field and click the search result.
  • Page 31: Order Table

    DN20 G inner thread, inc. pressure DN25 G inner thread, inc. pressure DN32 G inner thread, inc. pressure Standard range version of S418 A1453 Low range version of S418 A1455 Analogue 4 … 20 mA, pulse A1456 Digital Modbus/RTU...
  • Page 32: Error Codes

    Mains power supply 100-240 VAC / 24 VDC, 0.5 A, 2 m cable A554 0109 with M8 connector A553 0137 Connection cable S415/S418 to S551, 5 m M599 7020 S4A data analysis software, supports USB Gas type Gas type Natural gas (mix ratio) (oil &...
  • Page 33 S418...
  • Page 34 S418...
  • Page 35 S418...
  • Page 36 SUTO iTEC GmbH SUTO iTEC (ASIA) Co., Ltd. Grißheimer Weg 21 Room 10, 6/F, Block B, Cambridge Plaza D-79423 Heitersheim 188 San Wan Road, Sheung Shui, N.T. Germany Hong Kong Tel: +49 (0) 7634 50488 00 Tel: +852 2328 9782 Email: sales@suto-itec.com...
SUTO S418 INSTRUCTION AND OPERATION MANUAL Pdf Download (2024)
Top Articles
Latest Posts
Recommended Articles
Article information

Author: Duane Harber

Last Updated:

Views: 5701

Rating: 4 / 5 (71 voted)

Reviews: 94% of readers found this page helpful

Author information

Name: Duane Harber

Birthday: 1999-10-17

Address: Apt. 404 9899 Magnolia Roads, Port Royceville, ID 78186

Phone: +186911129794335

Job: Human Hospitality Planner

Hobby: Listening to music, Orienteering, Knapping, Dance, Mountain biking, Fishing, Pottery

Introduction: My name is Duane Harber, I am a modern, clever, handsome, fair, agreeable, inexpensive, beautiful person who loves writing and wants to share my knowledge and understanding with you.