$369.99 – $399.99
8 Analog Inputs (multi-function)
±1.28V, ±2.56V, ±5.12V, ±10.24V
4-20mA (Inputs 1-4 only)
Frequently Bought Together
24V DIN Rail Power Supply
ControlByWeb Cloud Device Seat
IRU-2423 Ultrasonic Sensor
LPD Loop Powered Display
- Description
- Accessories
- Demo
Multi-Function, 8-Channel Analog Input
The X-418 features an eight-channel, 16-bit, analog data acquisition system. Each channel is configurable as a single-ended or differential input. Programmable voltage ranges include; ±1.28V, ±2.56V, ±5.12V, and ±10.24V. Inputs 1-4 can be configured for 4-20mA operation. Monitor industrial sensors, pressure transducers, non-guided radar sensors, and more.
X-418 Features
- Email Notifications
- Customizable Web Dashboard
- Optional BASIC Scripting
- Robust Data Logging
- 400 Series Platform
X-418 Applications
- Industrial Sensor Monitoring
- Environmental Monitoring
- Tank Level Monitoring
- Process Monitoring
Powerful 400 Series Features
Integration Ready
We support HTTP GET, XML, JSON, SNMP, Modbus TCP/IP, and our Cloud API with more on the way.
No-Code Programmable Logic
Our intuitive Task Builder empowers you to build custom logic using drop-down menus in an if-this-then-that flow.
P2P Networking & Remote I/O
Devices can communicate through Peer-to-Peer (P2P) networking to share I/O among other ControlByWeb controllers, assign any device as master, set up multiple masters, and link remote inputs and relay control.
Email Notifications
Stay in control of operations with real-time monitoring. Add intelligence to your emails through programmable logic to instantly send notifications to the right people and eliminate false alarms.
Easy-to-Use Embedded UI
Our devices come with a simple embedded user interface that will enable you to easily monitor, manage, and control ControlByWeb PLCs from any standard web browser.
Data Logging
Enjoy scheduled and conditional logging with email and FTP log exports. Add the optional ControlByWeb Cloud for remote access and downloadable logs.
Cloud Compatible
Enhance your capabilities with the ControlByWeb Cloud. Gain enhanced features such as simplified remote device access, data logging, and advanced analytics.
Trusted Device Security
Our controllers have no built-in OS or file system, making them less prone to vulnerabilities. Third-party consultants and government agencies test the cybersecurity of our controllers.
IIoT Monitoring & Control
Access the device directly through an assigned IP address. Set up your network settings the way you want, to limit or allow remote access through the cloud.
X-418 Case Studies
View All Case Studies
Boiler Monitoring
Learn more
learn more
Warehouse Temperature Monitoring
Learn More
Specifications
Models
- X-418-I
- X-418-E
Power Requirements
- Voltage:
- X-418-I: 9-28 VDC
- X-418-E: POE and/or 9-28 VDC
- Max Current:152mA Max(See users manual for typical values at 25°C)
Analog Inputs
- Number of Inputs:8
- Resolution:16-bit, SAR
- Type:Single-ended, differential, 4-20mA (0-20mA), or a combination
- Input Range:
- Inputs 1-4: ±1.28V, ±2.56V, ±5.12V, ±10.24V, 4-20mA
- Inputs 5-8: ±1.28V, ±2.56V, ±5.12V, ±10.24V
- Max Input Voltage (Vin):-12.5V < Vin < +12.5V
- Input Impedance (Zin):> 500Meg Ohm
- Channel Off Leakage:±0.6nA (typ)
- Input Common Mode Rejection:>100dB
- Total Unadjusted Error:-9LSB (min), +9LSB (max)
- Voltage Reference Drift:±5 ppm/°C
- Internal 4-20mA input shunt:200-ohm, ±0.1%, 25ppm (uses ±5.12V range)
- Logging Rate:25 Hz
Real-Time Clock:
- Manual or NTP(Network Time Protocol) setup
- NTP Sync Period:Once, Daily, Weekly, On Powerup
- Auto Daylight Savings Adjustment
- Battery (capacitor) Power Backup
Capacitor Power Backup
- Backup Functions:Retain Real-Time Clock, 1 Register, 2 Counters
- Backup Duration:2 week minimum
Network
- Type:10/100 Base-T Ethernet Port
- Setup: Static or DHCP IP address configuration
Connectors
- Power and Inputs:14-Position, 3.81mm terminal spacing, Removable. For 16-28 AWG wire.
- Network:8-pin RJ-45
LED Indicators
- Number of LEDs:3
- Power on
- Network linked
- Network activity
Physical
- Operating Temperature:-40°F to 150°F (-40°C to 65.5°C)
- Size:
- 1.41in (35.7mm) wide
- 3.88in (98.5mm) tall
- 3.1in (78mm) deep (not including connector)
- Weight:5 oz. (142 g)
- Enclosure Material:Lexan 940 Polycarbonate Plastic
- Enclosure Flame Rating:UL94 V0
Protocols
- HTTP, HTTPS, SSL, XML, Modbus TCP/IP, SNMP, SMTP, Remote Services
Logging
- Log File Size:3,072K (up to 50,688 log entries depending on configuration)
- Storage:Nonvolatile Flash
- Buffer Architecture:Circular Buffer
Log data can be periodically read and stored on a computer
Advanced Features
- Task Builder
- BASIC interpreter
- Remote services
Password Settings
- Password Length:6-18 Characters
Regulatory Compliance
- Electromagnetic Compliance:
- IEC CISPR 22, CISPR 24, EU EN55024, EN55022
- X-418-I: FCC 47CFR15 (Class B)
- X-418-E: FCC 47CFR15 (Class A)
- Product Safety Compliance:
- IEC 61010-1
Manuals & Documentation
Users Manuals
400 Series Users Manual
X-418 Quick Start Guide (PDF)
Downloads
Firmware
X-418 Firmware v2.81
3D Model
X-418 3D Model (.stp)
Accessories
24V DIN Rail Power Supply
$74.99View Product
ControlByWeb Cloud Device Seat
$11.99View Product
IRU-2423 Ultrasonic Sensor
$739.95View Product
Power Supply | 12VDC
$19.99View Product
VEGAPULS C 11 Non-guided Radar
$795.00View Product
For your convenience we have set up a live X-418 unit for testing and evaluation. By clicking the links below you have full access to this live unit. You can make changes to the configuration and settings through the setup pages and you can control X-418 through its control page. The control page allows you to change the state of the relay and view the current state of the input.
Live Demo With One of Our Sales Engineers
Let’s make it easy with a live demo and screen sharing.
Set up a one-on-one Q & A with one of our experts. We’ll help you find the best solutions for your next project and walk you through a demonstration.
×
Schedule Free Consultation
Low on time? Watch a pre-recorded demo instead:
X-418 Setup
The diagram illustrates how this demonstration is wired. Nothing is connected to the relay contacts; however, you can still turn the relay on and off to see how it works. The input state only changes when a voltage is applied to the input. For this demonstration, we have connected one of our X-332 controllers to the input of the X-418. You can apply a voltage to the input of the X-418 by accessing the control page for the X-332 (Digital Input Control Page).
Important Information
- Multiple users may be accessing this device simultaneously so the device can change while you are using it.
- This unit will be reset to factory defaults daily at 2:30AM MST.
- Please DO NOT change network or password settings.
Related Products…
$369.99 – $469.99
The X-412™ is a powerful analog-to-digital Ethernet I/O PLC. It features 4 analog inputs, 4 relays, and a built-in web server for infinite control and monitoring possibilities. 4 Relays
4 Analog Inputs
New Cellular Option: The X-412CW model includes a cellular modem, compatible with our cellular data plans.
WiFi is Now Available. The X-412CW model includes WiFi capability which allows for more flexibility and cost savings for your application.[frequentlyBought ids="7624,7916,34491,7781"]
View Product
- X-420™ | Instrumentation-Grade Data Acquisition
$369.99 – $399.99
The X-420™ features software-programmable digital I/O that can be assigned as an input or an output. 4 Analog Inputs
2 Digital I/O
Up to 16 Temperature Sensors
[frequentlyBought ids="7621,34491,7916,7781"]
View Product
- X-22S™ | 8 Analog Input Expansion Module
$349.99
The X-22S™ eight-analog-input expansion module is used with an X-400™ or X-600M™ controller. It has eight precision analog inputs that can be configured for various voltage ranges and 4-20mA sensors. 8 Analog Inputs
Expansion Module for the X-400™ or X-600M™
[frequentlyBought ids="7635,7916, 22960"]
View Product